Electrification of lead oxide and zinc ore

A lead-zinc ore processing plant for disposal of lead and zinc ores mixed. There are dense ore-like ores in the ore, and there are also fine-grained oxidized ores. Mixed polyvalent metal ore with a mineral sphalerite, galena, pyrite, white lead, calamine, and hemimorphite lead alum. The gangue minerals are dolomite, calcite and a small amount of quartz and feldspar . Metallic mineral inlays are coarser in grain size. The oxidation rate of lead and zinc is higher (25%, 20%), and the raw ore contains 13% to 18%.
The selection process was pre-selected with heavy media, discarding approximately 36% of the tailings. Concentrate grinding of heavy medium beneficiation to -0.075mm accounted for 65%. The process of preferential flotation using lead sulfide, lead oxide, zinc sulfide and zinc oxide is shown in the figure below.

Graphic: Flotation process of a vulcanization-oxidation mixed lead-zinc mine

The amount of agent: xanthate 250g / t, black powder 50g / t, 2 # oil 240g / t, copper sulfate 1440g / t, fatty acid 80g / t, hydrochloric acid 80g / t, lime 1500g / t.

The obtained flotation index is: raw ore containing Pb 5.16%, containing Zn13.85%, lead concentrate containing 59.73% lead, recovery rate 87.2%, zinc concentrate containing Zn51.45%, recovery rate 80.94%.

Closed Cooling Tower

Why say closed cooling tower is energy saving and environmental protection equipment, more and more users are using this kind of equipment to replace the original equipment (open tower), we can through data analysis and comparison, the two energy data accounting can be obvious. Energy consumption is basically two major aspects, one is water, the other is electricity. Both are energy costs that no cooling tower can escape, unless you leave the equipment on.

First of all, look at the consumption of water. Water is generally consumed in two aspects. One is the flying overflow after spraying, and the other is the evaporation consumption of water.

Let's look at the open cooling tower, the spray water of the tower is basically between two and three percent of the overflow rate, if we according to the daily operation of 10 hours, excluding holidays, 280 days of operation. According to the actual open cooling tower flow of 6000 cubic meters per hour to calculate. 6000*2%*10*280= 336,000 tons of water, and the same closed cooling tower, its spray flying overflow is very small, because after all, the spray work is carried out in the tower, almost can be controlled in a few thousandths, we calculate according to 5 thousandths, the same is 10 hours of work, 280 days a year operation, To achieve the same cooling amplitude is basically 4,500 tons per hour of closed cooling tower is enough, then the calculation results: 4,500 *0.5%*10*280= 63,000 tons, it is not difficult to see, because of the different design structure caused by the waste of spraying water resources, more than 200,000 tons of terror. The bigger the pool of the open tower, the more wasted water, because the evaporation area increases, and the closed cooling tower has no pool, so the consumption here is zero. Judging from the price of a ton of water, just such a equipment, a year to solve the capital of hundreds of thousands of enterprises.

Let's look at the comparison of electric energy, electric energy is not different, because they are all through the same power equipment to operate the equipment, the power of the two is similar, the running time is the same, basically the energy consumption is about the same.

To sum up, for the closed cooling tower energy saving accounting can be strong to open the tower out, and, today are advocating energy conservation and environmental protection, this is the general trend, so the closed cooling tower is more and more favored by the majority of users.