Identify chemical composition of liquids, which is sealed in bottle or can.Â
*Applications: Control access security of airport, train station, subway, gymnasium, important government office, boarder seaport, and so on.Â
*Small size, high speed analysis, easy to operate.Â
*No radiation, harmless to people and test peopleÂ
*Advanced technology: Ultra-wideband pulse microwave reflection method and thermal conductivity technology
Â
Gerneral Specifications
Out size | Â Â 216*50*79mm(L*W*H) |
Identify dangerous liquid |  More than 30 sorts: Gasoline, kerosene, diesel oil , hydrochloric acid , sulfuric  acid , nitric acid , sodium hydroxide , potassium hydroxide , isopropyl ether ,  petroleum ether, propionaldehyde, benzene, carbon disulfide,hexane,  isopropanol, nitromethane, diethylamine , tris the trihalomethanes , ethylene  glycol, xylene and other flammable, corrosive liquids |
Component |  The host and the charging base |
Limited material of bottle |  can Iron, aluminum, plastic, glass, porcelain, china, pottery. |
Limitation of bottle | Â Bottle size no less than: 5.5cm*1.5cm, capacity no less than 50ml |
Single for safe liquid   |  Green LED light & short beep |
Data storage |  No less than 1000times test results are saved automatically. USB port available  to load down the data |
Alarm for dangerous liquid |  Red LED alarm light & long beep |
Single for safe liquid |  Green LED light & short beep |
Power on time | Â 1 second |
Identify time  Metal container |  within 8 seconds |
Other container |  with 1 second |
Weight | Â <200g (with battery) |
Temperature of container  | 5-35ºC |
Storage temperature / humidity |  -40ºC to 60ºC / 5% to 95% humidity |
Working temperature |  15ºC to 35ºC humidity / 5% to 95% humidity |
Power Voltage/ frequency | Â AC180-240V(50/60Hz)Â |
Power consumption   | 10W |
 Product Description
Identify chemical composition of liquids, which is sealed in bottle or can.Â
*Applications: Control access security of airport, train station, subway, gymnasium, important government office, boarder seaport, and so on.Â
*Small size, high speed analysis, easy to operate.Â
*No radiation, harmless to people and test peopleÂ
*Advanced technology: Ultra-wideband pulse microwave reflection method and thermal conductivity technology
Â
Gerneral Specifications
Out size | Â Â 216*50*79mm(L*W*H) |
Identify dangerous liquid |  More than 30 sorts: Gasoline, kerosene, diesel oil , hydrochloric acid , sulfuric  acid , nitric acid , sodium hydroxide , potassium hydroxide , isopropyl ether ,  petroleum ether, propionaldehyde, benzene, carbon disulfide,hexane,  isopropanol, nitromethane, diethylamine , tris the trihalomethanes , ethylene  glycol, xylene and other flammable, corrosive liquids |
Component |  The host and the charging base |
Limited material of bottle |  can Iron, aluminum, plastic, glass, porcelain, china, pottery. |
Limitation of bottle | Â Bottle size no less than: 5.5cm*1.5cm, capacity no less than 50ml |
Single for safe liquid   |  Green LED light & short beep |
Data storage |  No less than 1000times test results are saved automatically. USB port available  to load down the data |
Alarm for dangerous liquid |  Red LED alarm light & long beep |
Single for safe liquid |  Green LED light & short beep |
Power on time | Â 1 second |
Identify time  Metal container |  within 8 seconds |
Other container |  with 1 second |
Weight | Â <200g (with battery) |
Temperature of container  | 5-35ºC |
Storage temperature / humidity |  -40ºC to 60ºC / 5% to 95% humidity |
Working temperature |  15ºC to 35ºC humidity / 5% to 95% humidity |
Power Voltage/ frequency | Â AC180-240V(50/60Hz)Â |
Power consumption   | 10W |
Â
HFCs (hydrofluorocarbons) are the third
generation of fluorine-based gases.
These products are categorised as having zero ODP (Ozone Depleting Potential)
and medium to high GWP (Global Warming Potential) and so offer a more
environmentally friendly alternative to CFCs and HCFCs.
HFCs are used in a wide range of refrigeration and air conditioning equipment
specifically designed for them, and as "drop
in" retrofit gases for older CFC or HCFC equipment. HFCs are also
used in selective propellant and foam blowing
applications.
A growing focus on the environmental
impact of refrigerants is fuelling demand for refrigeration solutions
that can provide satisfactory cooling performance with a lower impact on global
warming. This is propelling environmentally friendly refrigeration solutions to
the top of the corporate sustainability agenda. In addition, local legislation
is increasingly targeting refrigerant gases with high GWP.
Zhejiang Zhonglan Refrigerants Co.,Ltd offers a number of lower GWP HFC solutions, such as R134a, R404a, R406a, R407c, R410a, R507,R417a,R422d,R125,R32, etc. For new equipment purchases, we also supply a wide range of HFC alternatives. These include HC(natural refrigerants), which provide a viable, lower GWP alternative to HFCs.
HFC Refrigerant Blends,Freon Refrigeration,Blend Refrigerant Gas,Mixed Refrigerant Gas
Zhejiang Jinze Refrigerant Co.,Ltd , https://www.uiszl.com