Remote reading system of water meter
Remote water meter reading is a kind of application for automatic meter reading.Meter reading and data management can be achieved through the client management software, do not need to go to the scene, can greatly improve the work efficiency.When the field is installed, the camera remote water meter is incorporated into the M-BUS bus, and then the bus is connected with the collecting machine.Meter reader can send commands through the client management software to the meter reading acquisition machine. After receiving the command, the collection machine begins to automatically carry out the meter reading to the water meter.Meter reading data through the acquisition machine comes with the GPRS module to send to the server.
Camera remote water meter consisted of installing the camera sensor on the original meter with the structure,is completely separate structure and the original meter do not need to be changed.Assembly is simple and easy to operate.The circuit module is not under pressure.The structure prevent the faults caused by the water entering the sealed cavity. When replacing the original meter,camera sensor can be used repeatedly.
Picture is truthÂ
The photos of the word wheel window on the water meter and data can be show in the meter reading management software at the same time. The meter-reader can complete checking the water meter reading in the meter reading application.
No error of meter reading
The photos of the word wheel window on the water meter can be getting when the water meter be reading with no measurement error existing.Â
Excellent waterproof function
Camera sensor interior used of special waterproof structure, which can prevent external dust and moisture to inducing circuit fault . Camera sensor can adapt to a variety of complex conditions.Â
Exempt from Debugging
When installing, the camera remote water meter can be installed directly in the pipeline, without debugging.Installation of high efficiency, significantly shorten the project delivery cycle.
Power supply |
DC24-36V |
work environment |
0ºC-45ºC |
Bus interface |
M―Bus |
Communication parameters |
2400,8,e,1 |
Communication transmission maximum distance |
1000m |
Communication cable |
 Twisted-pair RVV2 core x 1 mm² |
communication protocol |
CJ/T 188-2004 |
quiescent current |
<1mA |
working current |
<50mA |
Non partition filter uses hot melt adhesive instead of aluminum foil with partition filter to separate the filter material
filter,partition,line
ChangZhou FENGJU Machinery Equipment CO., LTD , https://www.nbfengjumachinery.com